Product/Categories

Quantel

AVISO

AVISO

A/B mode ultrasound driven PC system

Biometry
Biometry in B mode
IOL calculation
10 & 20 MHz probes
Linear UBM 50 MHz probes

Unique work station concept

Controls are intuitive and always accessible

  • Remote control touch screen provides control at your fingertips
  • Access functions and controls with a single click

Powerful post processing function

  • User-friendly patient and user data base
  • Automatic image recording with Cineloop
  • Adjustable gain on frozen pictures with Varigain
  • User post processing tools: calipers, areas, markers, comments

A modern design adapted to your working environment

  • Portable - use AVISO as your primary system or take it to your satellite clinics
  • Probe holder: safe, practical, 180° orientation

Easy to use and intuitive software

AVISO, user friendly software

  • Simple icons on PC and remote control touch screen
  • Main tool bar always visible
  • 3 dedicated zones: Controls / Images / Navigation
AVISO

AVISO, a networking system

  • Connect to medical servers (DICOM, EMR standards)
  • Print patient report (up to 8 images)

Adapted to your needs: 7 probes

Linear scanning: technical innovation

AVISO
  • Lin50: linear 50 MHz UBM probe
  • Lin20: linear 20 MHz UBM probe
  • Specifically designed for the anterior chamber and measurement

B-scan examination with 20MHz high frequency probes & 10MHz probe

  • 20 MHz probe for anterior chamber: View the anterior chamber from sulcus to sulcus
  • 20 MHz probe for posterior segment: Provides high resolution images of the retina even with opaque media
  • 10 MHz probe: Exquisite visualization of the globe and the orbit

Precision biometry

2 biometry probes:

  • Standard probe
  • ProBeam™ * with a unique laser aiming beam: faster & easier to use, avoids problem of misalignment

(*) Patented by Quantel Medical

Cinescan

Cinescan

High resolution analog A/B scan system

Why Analog Technology?

  • Provides real time B-Scan images
  • Offers 8 times more contrast ratio
  • Offers 4 times more resolution
  • 256 level grey scale for superior differentiation of pathology
  • Selected as the standard in teaching centers worldwide

Obtain a precise visualisation of the pathologies to make the diagnostic self-evident

Functions which make the examination fast and easy:

Cineloop: view up to 39 images, frame-by-frame to quickly find missed pathology
- View the "movie" to make a dynamic diagnosis or show the patient or caregiver the detachment in motion.

Varigain: to save time and for an improved diagnosis.
- The Gain and Dynamic can be adjusted on a frozen image to Illuminate or de-illuminate the pathology

Vplus: gain setting up 105 dB
- Improve the visualization of the low reflective structures particularly in the vitreous

3 levels of zoom:
- Adjust the image size and see a magnification of the pathology

Visuscan: transfer images and patient data to a Laptop or PC, with proprietary software

A simple keystroke, quickly and easily, provides access to all functions

Precision A-Scan Biometry:

  • Fast acquisition
  • Precision equivalent to the laser interferometer with immersion technique (*2)
  • Lightweight probe compatible with the slit lamp tonometer holder

(*2) Bibliography:
Immersion A-scan compared with partial coherence interferometry. Outcomes analysis. (Mark. Packer, MD, I. Howard Fine, MD, Richard S. Hoffman, MD, Peggy G. Coffman, COT, Laurie K. Brown, COMT, COE - Journal of Cataract & Refractive Surgery, Vol. 28, No. 2, February 02)
Precise measurements for an optimal IOL calculation result

Unique and invaluable Standardized Echography, by Karl C. Ossoinig, MD – a Quantel Medical exclusive (*1): Cinescan S

The principle:
Using specific amplification and analysis of internal tissue reflectivity, Standardized Echography offers advanced diagnostic capability for the Retina Specialist

Complete and improve the diagnostic by a characterization of the tissues

Only system approved by the American Association of Standardized Echography (AASOE). The CINESCAN S has been developed in partnership with Prof. Karl C. Ossoinig M.D.

B-Scan examination with 10 MHz and optional High Frequency Probes:

Quantel Medical's probe technology:

Closed probes with protected transducers:

  • Easy cleaning and durability in use
  • Preclude possibility of corneal abrasion

10 MHz Probe:

  • Exquisite visualization of the globe and the orbit
  • High sensitivity offers unsurpassed images of low reflective structures
  • Offers unsurpassed images of the low reflective tissues

Optional, High Frequency Posterior Segment Probe:

  • Offers twice the resolution of a 10 MHz probe
  • Provides high resolution images of the retina even with opaque media and when OCT cannot obtain any images
  • Real time visualization of all the scanned areas

Open new fields of investigation in retinal Ultrasound imaging

Optional, High Frequency Anterior Segment Probe:

  • View the anterior chamber from sulcus to sulcus
  • No scleral shell required – it's faster for the user and more comfortable for the patient

A useful tool for a precise measurement and large diagnostic possibilities of the anterior chamber

Biometry in B Mode:

  • Precision biometry from a B-Scan image
  • Always ensures measurement in the visual axis
  • Perfect for difficult to measure long eyes or posterior Staphyloma
  • No contact with the cornea thanks to the pseudo-immersion technique
  • Automatically positions gates and places measurements into biometry software for fast IOL calcuation
  • Simultaneous viewing of the posterior pole for analysis

Allows axial length measurement in 100% of your patient

For more info, check the official Quantel Medical website.